Mark E.

Mark E. Job Checkin

Return to continue diagnostics and start up with Rene and wine cellar unit- was pulled from the job to head someplace else- Rene still on site continuing diagnostics as system is not working properly after startup and continuous changes


julio@innovativeairsolutions.com

julio@innovativeairsolutions.com Job Checkin

Return to adjust pressures and setting according to manufacturer standards: - system is on and running at arrival - The system is satisfied at the thermostat and set temperatures - Connect gauge is to outdoor condenser and lower setting on thermostat for system to turn on - Indoor air filter is clean and clear - System has been charged accordingly to the line set length - Both condenser and indoor air handler are on and running - Check super heat and sub cooling- the super heat is not at manufacturers standards - The manufacturer has recommended to adjust the TXV with 1/2 turns, turn the system off and wait 15 minutes- and then turned back on and recheck - Had to repeat this process, almost a dozen times to get the correct readings - Confirm airflow and temperature splits inside- okay - Evaporator coil is cold and producing condensate - Tested the condensate pump and discharge line to confirm normal operations - Take all readings and note for manufacturer - Close up access point in


julio@innovativeairsolutions.com

julio@innovativeairsolutions.com Job Checkin

Return to replace txv on wine cellar unit. Removed racks and door from wine cellar to access air handler. Reclaimed all of the refrigerant and removed evaporator coil to access txv. Cut out txv and pro pressed a new valve to the coil. Pressurized system for leaks and no leaks were found pulled a vacuum and recharged the unit with 4.8lbs of 134a according to manufacturer standards. Ran the system and checked all operations. Will need to return to fine tune the system will need two techs. Need to make adjustments to the txv to adjust superheat to system.


julio@innovativeairsolutions.com

julio@innovativeairsolutions.com Job Checkin

return to diagnose issue with wine cellar not working spoke to tech support and they mentioned that there is a restriction and that the txv needs to be replaced. need to recover refrigerant, remove and install new txv, nitrogen pressure test for leaks, pull a vacuum and recharge the system to manufacture standards. Office to order txv and schedule repair.


julio@innovativeairsolutions.com

julio@innovativeairsolutions.com Job Checkin

Service call for wine cellar unit not operating system was freezing up and was left off in order to thaw out the system. Returned and inspected indoor air handler system and all of the ice was thawed out. system was turned on and pressures were checked. The low side pressure is pulling down in to a vacuum -20 and the high side pressure is 115-130 psi. Unit has a bad txv that needs to be replaced office to follow up on replacement part. All of the refrigerant has to be reclaimed, replace txv, nitrogen pressure test and recharge. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A3D0-066053A6F15C40569650ADE180E7E800


Richard  .

Richard . Job Checkin

Today I arrived on site to address the wine cellar's cooling issue. Issue Identification: The wine cellar for the winery room was not cooling effectively. Problem Diagnosis: I discovered the wine cellar was frozen. Resolution: The dehumidifier breaker had tripped. Upon arriving at the property. I contacted Johanna to get access to the property. Johanna was not available to get to the property. They sent George to dismantle the panel to have access to the indoor unit in the winery room. I proceeded to verify the system. I found the TXV frozen. Contact tech support to diagnose this system. System operate in R133A. Tech support it occurred to me that it will turn off the system for 24 hours until the system is thawed. I explained to the owner about the situation. The owner also mentioned that the humidifier was not working in the basement. I proceeded to check the humidifier. I found the circuit breaker tripped. I put the breaker in on poison. The dehumidifier began to operate. I monitor


Nigel  B.

Nigel B. Job Checkin

Completed maintenance on three AC systems checked electrical and mechanical components and electrical connections also flush and tested condensate drain lines with one gallon of water per system turned systems on and checked system operation and refrigerant levels left systems working


Lorenzo M.

Lorenzo M. Job Checkin

I/W Follow up is needed. Need to reclaim x2 system refrigerant charge. 1st floor and Basement system is operating with high head pressures ( basement system-short cycle occasionally) 1st floor system was found in a lockout History of system operation: Today I arrived on site to address issues with the basement and main floor AC systems. AC System Inspection: Found both AC systems displaying an error. Corrective Actions: Reset systems. Adjusted pressures. Upon arriving at the property, the customer mentioned that two of the systems are not operating properly. The customer said that the outdoor units turn on and off consecutively(Basement). I proceeded to check the condenser units of the 1st floor and the basement. I found both units displaying an error code related to head pressure too high. The pressures of the systems were a little high. Normalize the pressures for the moment. I ran the systems and monitoring for about 20-30 minutes. The systems did not fail at the time of monitoring


Lorenzo M.

Lorenzo M. Job Checkin

Upon arrival spoke with customer who’s informing me that leak was coming from around daughter’s bedroom return grill. Inspected air handler in attic kneewall. A lot of air leakage is coming from supply plenum. Sealed supply plenum with aluminum tape. Try to locate return flex in question. Was unable to do so due to attic limitations and supply and return flex being tied into ERV. Condensate drain was flush and tested. Condensate pump discharge normally. Customer is aware that attic flooring is not insulated and issue seem to be related to condensation around return grill. Customer will monitor conditions of return grill. Insulation department may need to be involved. System is operating normally @ this time no signs of leak was visible @ return grill or on ceiling below air conditioning unit. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-FA02-01792B21888B4DDF8CBFED2DECEBD76F


julio@innovativeairsolutions.com

julio@innovativeairsolutions.com Job Checkin

Service call for error code on thermostat. This is a daikin ducted unit that serves the kitchen and another room off of the kitchen there are two zones and the air handler is located in the attic with a pull down stair case. The thermostats were giving an error code of E3 indicating high pressure. System was reset checked air filters and coils. Air filter is not dirty and in good condition also coils are not dirty to cause a high pressure issue. After resetting system was on and running checked pressures and all operations system is currently operating with out any faults. Customer had a coupon for a free service call. Customer will monitor system and call back if any issues. https://visionshare.xoi.io/?id=ms091f0d6d-575d-i184-85e44cd1946e-uF83-61b55d9b47af


Lorenzo M.

Lorenzo M. Job Checkin

Upon arrival inspected 2nd floor furnace. Follow up to check if furnace has gas leak. Opened gas valve that was left in the off position. Checked all gas joints with gas leak solutions. No leak. Not smelling anything @ unit. Check all other gas line in mechanical room. 1st floor furnace gas lines. HWH gas line and Main gas line that’s distributing gas to all appliances. Unable to confirm any gas leak or smell @ this time. Office will follow up customer to schedule extensive diagnostics with plumber/tech Gas is left off @ emergency shut off. Follow up is needed View visual findings from this job here - https://visionshare.xoi.io/?id=XA-FA02-CE59A9E8FE854D3F9F3F8EEAEC2CF877


Lorenzo M.

Lorenzo M. Job Checkin

8 Foot Ladder is needed to Access 2nd floor Air Handler. Very High ceiling access. Upon arrival inspected air handler for 2nd floor air handler. Removed electronic air filter @ return to expose evaporator coil. Remove all door covers @ indoor air handler. Searched evaporator coil with UV light. Saw streak of dry on evaporator coil @ multiple locations. Air handler is 16 yrs old. Advising customer to consider replacement options. Searched Condenser. Remove fan motor. Cover condenser with blankets to create dark room effect to search interior of outdoor coil. Dry search for outdoor is inconclusive @ this time. Possibility of dye showing up @ a later time. Condenser is 15yrs old. Advising customer to consider replacement option. Customer would like office to provide quote for replacement of 2nd floor system View visual findings from this job here - https://visionshare.xoi.io/?id=XA-FA02-E4E2A3A47D4448198EB17770E4755200


Mark E.

Mark E. Job Checkin

Ac maintenance on x7 systems

Ac maintenance on x7 systems

Antonio S.

Antonio S. Job Checkin

Boiler tune up

Boiler tune up

Antonio S.

Antonio S. Job Checkin

Heat pumps tune ups

Heat pumps tune ups